Figure 1

Septic Sysytem Design Bolivia

CE4905 Senior Design 2003
Slide Show Scenes of 2003 Projects


Figure 2
<
   

THE PLAN

  • Design a Complete Septic System for a
    Future School of 500 Students
  • Include Local Building Practices
    in the Design
  • Secure Funding, Materials and Labor
  • Build the Septic Tank, Sedimentation
    Basin and Adsorption Field


Figure 3
 

THE DESIGN

Three Steps to Clean Waste

1. Two Chamber Septic Tank
2. Sedimentation Basin
3. Adsorption Field

 


Figure 4
  SEPTIC TANK DESIGN

Two compartment tank provides better
suspended solids removal
2.2 Gallons H20/student/day
Detention Time = 48 hrs
Tank Volume = 2,200 gal = 294 ft3
Tank Dimensions = 6’ x 13’ x 4’


 
 

SEDIMENTATION BASIN


Volume = 740 ft3

Dimensions:
Diameter= 6.5 ft
Height = 7 ft

Slide Show Scenes of 2003 Projects

  ADSORPTION FIELD 

Percolation rate = 4.5 min/in of fall
Max rate of sewer application
= 2.42 gal/ft2/day
Expected flow = 1,100 gal/day
Area for adsorption = 460 ft2
Trench Length = 170 ft